f710.jpg


Features & benefits

FeatureBenefits
IBM Variable Stripe RAID technology
IBM MicroLatency
Superior flash media technology


Specifications


  IBM FlashSystem 810 and IBM FlashSystem 710 at a glance*
SeriesIBM FlashSystem 810IBM Flash System 710
Model9830-AE19830-AS1
Flash typeeMLCSLC
Usable capacity (terabyte [TB]/ tebibyte [TiB])10.3 TB/9.4 TiB5.2 TB/4.7 TiB
Raw maximum capacity (TB/TiB)13.7 TB/12.5 TiB6.9 TB/6.3 TiB
Incremental usable capacity upgrade (TB/TiB)2.1 TB/1.9 TiB1.0 TB/0.9 TiB
Minimum latency
Write60 µs60 µs
Read110 µs100 µs
Read (from host)160 µs145 µs
Maximum IOPS 4 KB
100% read550k570k
Mixed 70/30% read/write430k490k
100% write400k400k
Maximum bandwidth 256 KB
Read3.3 GB/s (Fibre Channel)
5 GB/s (InfiniBand)
3.3 GB/s (Fibre Channel)
5 GB/s (InfiniBand)
Write2.8 GB/s (Fibre Channel)
2.8 GB/s (InfiniBand)
3.3 GB/s (Fibre Channel)
4.5 GB/s (InfiniBand)
Power350 Watts280 Watts
Cooling1194 BTU/hr.955 BTU/hr.
ReliabilityModule-level Variable Stripe RAID
Redundant interfaces
Redundant and hot-swappable power supplies
N+1 batteries
2n fans
Error-correcting code
Checksums
Data integrity fields
Supported RAID levels0
Connectivity options4 x 8 Gb/s Fibre Channel
4 x 40 Gb/s QDR InfiniBand
Client operating system supportFor a current list of platforms supported, please visit the IBM System Storage Interoperation Center (SSIC)
Maximum volume support (LUNs)1,024
Management interfacesWeb, SSH, Telnet and more
Enclosure dimensions (H x W x D)1U x 432 mm x 569 mm (1U x 17 in. x 22.5 in.)
Weight11.3 kg / 25 lb
Environmental requirements10°C – 35°C (50°F – 95°F) operating temperature at -30.5 m – 300 m (-100 ft – 984.25 ft)
altitude -10°C – 50°C (14°F – 122°F) non-operational
20% – 80% RH operating
10% – 90% RH non-operational
0.1g rms operational vibration
0.8g rms operational shock
3.5g 3ms half-sine pulse vertical non-operational
Regulatory complianceSafety: IEC/EN 60950, CB Certificate, UL60950-1 CAN/CSA-C22.2 No.60950-1, CE Mark
Emissions Class A: EN55022/CISPR 22, FCC Part 15 Class A, ICES-003 Issue 4 Class A

  1. IBM FlashSystem 810 and IBM FlashSystem 710(영문)

    Features & benefits FeatureBenefitsIBM Variable Stripe RAID technologyMaintains performance while enhancing reliability—without sacrificing usable capacity IBM MicroLatencyEnables faster decision making by facilitating an extreme-perfor...
    Category플래시 스토리지 시스템
    Read More
  2. IBM FlashSystem 820 및 IBM FlashSystem 720

    Features & benefits 특징이점IBM Variable Stripe RAID 기술가용 용량을 저하시키지 않고 성능을 유지하면서 동시에 안정성 향상 "장애 지점이 전혀 없는" 아키텍처가장 처리량이 많은 데이터 센터를 위한 엔터프라이즈급 안정성 및 효율성 제공 우수한 ...
    Category플래시 고가용성 스토리지 시스템
    Read More
Board Pagination Prev 1 Next
/ 1
©2013 KSODESIGN.All Rights Reserved